May Lead To Delamination Of The Roof Sheathing

This is sometimes accompanied by buckling.
May lead to delamination of the roof sheathing. What is the spacing requirements between the insulation and the roof deck sheathing at the location of the vent. I had my roof sheathing replaced a year ago. But probably not due to the amount of delamination. That being said what the home inspector saw may or may not be mold.
The horizontal board enclosing the ends of the rafter projections or tails is normally referred to as the board. The attic was vented by soffit and a ridge vents. One of the implications of high moisture levels from either condensation or leakage is delamination of plywood sheathing. Defects in those sheets or it could be that the ventilation was blocked only at those sheets.
Depression between the rafters. The contractor thought it might have been due to excess moisture in the attic. This winter i went up. Roof decking plywood delamination if you have a home twenty five years or older you may want to consider the condition of the plywood.
High moisture levels break down the glue in the plywood and allow the plies to delaminate. Panel type roof sheathing may lift off the rafters in a regular pattern. Leaks around deteriorated flashing are the most common. In determining if it is.
Delaminations commonly affect single ply and fully adhered roofs. The soffits didn t appear to be congested with insulation however the ridge vent had a filter in place. 3 8 plywood roof sheathing. Between the years of around 1964 to 1975 homes being built saw the installation of what was first generation fire retardant plywood.
De lamination of the roof sheathing may cause. Particularly on the roof. When the membrane and insulation separate. It may be mfgr.
Every re roof requires a close inspection of the substrate. In the future looking for a date stamp on the affected sheet or other sheets in the same general area may help an apa rep. This may be indicative of what. To improve it make sure your home has continuous ridge and soffit ventilation.
It was plywood and had delaminated. First deal with the cause which is inadequate attic ventilation. The worst cases result in patches of rot. If this is the case the solution is twofold.
In the attic the roof sheathing appears to be delaminating and some staining was observed. Incidental roof leaks particularly ones that go unnoticed can delaminate plywood sheathing or cause osb to swell. Like blisters delamination can come from improper installation in inclement weather.